Sprinkler winterizing

How to winterize a sprinkler system

Shut the water off, get the water out of the pipes, and protect the backflow preventer. Hunter caps blow-out air at 50 psi on poly pipe and 80 psi on PVC, and Rain Bird’s homeowner guide says 50 psi. Never push air through the backflow.

  • ≤ 50 psi poly / ≤ 80 psi PVC
  • Air downstream of the backflow
  • One zone open first
  • Hunter Clik freeze shutoff 37°F

Checked against manufacturer specifications and our live catalog · Updated October 2026

Hunter wireless rain sensor on a wet gutter
Rain sensor on the gutter
Hunter PGV valve in a valve box before a blow-out
Valve before the blow-out

Short answer

Close the irrigation shutoff and set the controller to Off. Remove the water by manual drains, automatic drains, or compressed air connected after the backflow preventer, with a zone valve open first. Hunter limits air to 50 psi for polyethylene and 80 psi for PVC; Rain Bird’s homeowner guide limits it to 50 psi. Then drain the backflow and leave its ball valves half open.

1

Shut off and set the controller

Close the irrigation shutoff valve and insulate it. Set the controller to Off; you do not need to erase the program.

2

Drain or blow out the lines

Connect the compressor after the backflow preventer. Open a zone before the air goes in. Stay at or under 50 psi on poly pipe and 80 psi on PVC (Hunter); Rain Bird’s homeowner guide says 50 psi.

3

Drain and protect the backflow

Open the backflow’s test cocks to drain it, then leave the ball valves half open so water cannot be trapped and freeze inside. Insulate above-ground pipe.

Blow-out numbers

Pressure and air volume

ItemNumberSource
Max air pressure, polyethylene (flexible black) pipe50 psiHunter; Colorado State University Extension
Max air pressure, rigid PVC pipe80 psiHunter; Colorado State University Extension
Max air pressure, homeowner blow-out50 psiRain Bird winterization guide
Compressor air volumeLargest zone GPM ÷ 7.5 = CFMHunter
Compressor air volume, typical home10–25 CFMRain Bird winterization guide
Hunter Clik sensor freeze shutoff37°FHunter listing

When the pipe type is unknown, use 50 psi. High-volume, low-pressure air removes water better than a tank charged to high pressure.

Parts we ship

Freeze protection and spring repairs

Most freeze damage shows up in spring at the backflow preventer. Bonnet and poppet kits are cheaper than a new assembly.

Match the symptom

What you find in spring

What you seeWhat to doStart here
PVB leaks or sprays from the top capFreeze damage to the bonnet or poppet. Rebuild with the kit for that size; replace if the body is cracked.3/4 in. bonnet · 1/2–3/4 in. poppet kit
Bronze backflow body is splitReplace the assembly. Have it tested if your water provider requires it.Febco 765 3/4 in.
Sprinklers ran during a freezeAdd a rain and freeze sensor so the controller skips cold mornings.Wireless Rain-Clik
A zone will not start in springRun the valve test: bleed by hand, then check voltage and the solenoid.Valve guide
Wet spot over the mainlineA split pipe from trapped water. Send a photo and we will spec the repair fittings.Send a photo

The steps people skip

What ruins a blow-out

  1. Never blow air through the backflow preventer. Hunter and Colorado State University Extension both say to connect after it. Air can damage the internal parts.
  2. Open a zone before the compressor. Rain Bird’s guide says never run the compressor without a zone valve open.
  3. Do not stand over pipe, valves, or heads. Wear eye protection. Do not leave the compressor unattended.
  4. Use air volume, not tank pressure. Hunter warns against charging the tank high and dumping it into the mainline.
  5. Keep cycles short on rotors. Rain Bird warns that long air runs heat gear-drive rotor seals.
  6. Leave the backflow ball valves half open. Colorado State University Extension: return the isolation valve to half open, half closed after the blow-out.
  7. Close manual drains afterward. Hunter: do not leave manual drain valves open after the blow-out.
  8. Drain valves alone may not be enough. Colorado State University Extension advises blowing out even systems with drain valves, because water stays in low spots.

Common questions

What PSI should I use to blow out sprinklers?

Hunter says not to exceed 50 psi on polyethylene pipe or 80 psi on PVC. Rain Bird’s homeowner winterization guide sets 50 psi as the limit. If you do not know your pipe, use 50 psi.

What size air compressor do I need?

Hunter’s formula is the GPM of the largest zone divided by 7.5 for the CFM needed. Rain Bird’s homeowner guide calls for roughly 10 to 25 CFM for a home system. Small shop compressors often cannot keep up.

Can I blow air through the backflow preventer?

No. Connect the compressor to a fitting after the backflow preventer. Hunter and Colorado State University Extension both say not to blow compressed air through it.

Should I turn the sprinkler controller off or unplug it?

Set it to Off. The program does not need to be erased, and spring start-up is just switching it back on.

Are automatic drain valves enough?

Colorado State University Extension advises blowing out the system anyway, because drain valves can leave water in low spots.

Is a freeze sensor a substitute for winterizing?

No. A freeze sensor only stops scheduled watering near freezing (37°F on Hunter Clik sensors). It does not remove water from pipes or protect the backflow preventer in a hard freeze.

Where do I connect the compressor?

At a blow-out fitting, quick coupler, or hose connection located after the backflow preventer, with the backflow’s downstream isolation valve closed.

Sources

Send a photo of the backflow preventer

Tell us the brand and size on the body. We will match the bonnet, poppet, or replacement assembly. Free US shipping.

Terms & Conditions of Sale

PLEASE READ THIS DOCUMENT CAREFULLY. IT CONTAINS VERY IMPORTANT INFORMATION REGARDING YOUR RIGHTS AND OBLIGATIONS, INCLUDING LIMITATIONS AND EXCLUSIONS THAT MIGHT APPLY TO YOU.1. Agreement Scope: When you order products from the Big Irrigation Supply website, you agree to these terms. The supplier can change these terms without notice, and the most current version will be on the website.2. Order Acceptance and Cancellation: The supplier may accept, decline, or limit your order for any reason after receiving it. If your order is canceled after your card is charged, you will be refunded. Minimum order amounts apply and can change without notice. Customer cancellations will incur a credit card charge up to 4%.3. Pricing: Prices are subject to change and do not include taxes. Any taxes applicable will be added to the price, and you must either pay them or provide a tax exemption certificate.4. Payment Terms: Full payment is required before shipping, and you can pay online via credit card.5. Shipping and Risk: Ownership of the products transfers to you either when the products leave the supplier’s location or when they are delivered to your address, depending on the delivery method. You are responsible for shipping costs and must inspect deliveries for damage or discrepancies upon receipt.6. Warranties and Returns: Products are generally covered by the manufacturer’s warranty, details of which are provided in the product description or manufacturer’s website. Returns require prior authorization and must be made within specific time frames. A restocking fee may apply of up to 35%. Non-returnable items from Big Irrigation Supply specifically include all landscape lighting fixtures and transformers, as well as irrigation commercial controllers like MC-E and ACC2 models. Additionally, any items that are not regularly stocked or are special order items cannot be returned.7. Intellectual Property: The supplier owns any content, inventions, or intellectual property developed during the term of your agreement with them.8. Advertising and Liability: The supplier is not responsible for inaccuracies in product descriptions provided by their suppliers, nor for typographical or pricing errors. They also disclaim all implied warranties and limit their liability for any damages arising from the use of their site to the amount you paid for the products.9. Indemnification: You must defend and indemnify the supplier against any claims or damages arising from your use of the products, or any breach of these terms.10. Legal: The agreement is governed by the laws of Texas, and any disputes will be handled in Collin County, Texas, without a jury trial.11. Force Majeure: The supplier is not liable for delays or failures in delivery caused by circumstances beyond their control, such as natural disasters or labor strikes.12. Miscellaneous: If part of these terms is found to be unenforceable, the rest still applies. Provisions that by their nature should survive the termination of the agreement will do so.